Application And Installation Of Sanitary Stainless Steel Manual Aseptic Sampling Valve

Place of Origin:
Wenzhou, China
Packing:
Suitable Packing for Sea/Air Transport
Quantity:
10000 PCS Per Year
Payment:
T/T, L/C, Western Union
Material:
SS304, SS316L
Connection:
Clamped
Type:
Aseptic

To prevent sampling errors, install a sanitary sampling valve with SS316L wetted parts, SS304 non‑wetted parts, and PTFE diaphragm at tank outlets or pipeline ports. Clamped connections allow tool‑free removal. Sizes DN6–DN15. Operation: sterilise the chamber with steam at ≤3 bar, lift the handle to draw the sample, close and re‑sterilise. Replace the PTFE diaphragm after 100 cycles or every 6–12 months. This protocol ensures each sample represents actual batch quality.

What Constitutes a Sampling Error

A sampling error occurs when the extracted sample does not represent the actual batch composition.

  •  Residual cleaning fluid or stagnant product in the port

  •  Microbial contamination introduced during sampling

  •  Cross‑contamination between batches

These errors cause out‑of‑specification results, batch rejection, and deviation investigations costing days of production time.

How Aseptic Design Eliminates Contamination

This stainless steel sample valve uses a PTFE diaphragm that seals the body when closed. Wetted parts are SS316L – specified for pitting resistance and steam compatibility – and non‑wetted parts are SS304. Internal surfaces polished to Ra ≤ 0.8 µm reduce bacterial adhesion. The sample chamber isolates from the process line until sampling initiates.

Sampling Procedure Step by Step

  • 🔹 Sterilise the chamber with saturated steam at ≤3 bar

  • 🔹 Inject steam through one port, exhaust from the other

  • 🔹 Maintain sterilisation temperature for required hold time

  • 🔹 Lift the manual handle – the diaphragm retracts from the inlet

  • 🔹 Process fluid flows through the chamber to the collection port

  • 🔹 Close the handle – spring tension reseals the diaphragm

  • 🔹 Flush residual liquid with clean water or sterile medium

  • 🔹 Re‑sterilise the chamber and seal for next use

Material Selection and Diaphragm

SS316L wetted parts resist chloride‑induced pitting and withstand steam sterilisation up to 150°C. SS304 non‑wetted components reduce cost without affecting process contact. The PTFE diaphragm offers non‑stick properties and steam resistance – unlike elastomers, PTFE does not degrade from repeated exposure. A manual handle moves the stem axially, compressing or releasing the spring. Spring‑loaded closure seals immediately when the handle releases. No external power required.

Clamped Connections and Installation

Clamped (Tri‑Clamp) connections allow tool‑free removal – loosen the clamp, separate ferrules, and lift the valve body. Diaphragm replacement takes under 10 minutes. A hygienic sample valve requires horizontal centre‑line installation with the sampling port oriented vertically downward for complete drainage. Clamped connections allow rotation for optimal port positioning.

Specification Value
Wetted material SS316L
Non‑wetted material SS304
Diaphragm PTFE
Connection type Clamped (Tri‑Clamp)
Size range DN6, DN8, DN10, DN15
Working pressure ≤8 bar
Sterilisation pressure ≤3 bar
Working temperature –10°C to +120°C
Sterilisation temperature 120–150°C
Surface finish Ra ≤ 0.8 μm

CIP and SIP Compatibility

Sample valves sanitary in design support Clean‑in‑Place and Steam‑in‑Place without disassembly. CIP fluid flows through the body to remove residues. SIP at 121°C or higher sterilises all wetted surfaces. The PTFE diaphragm withstands repeated steam cycles. Clamped connections remain sealed under both conditions.

Maintenance Protocol

The diaphragm is the only wearable component. Inspect for loss of elasticity, cracking from thermal cycling, or surface scoring. Replace after 100 sampling cycles or every 6–12 months. Tri‑Clamp access allows complete diaphragm replacement in under 10 minutes – loosen clamp, remove body, disassemble, install new diaphragm, reassemble.

Frequently Asked Questions

Q: Sampling valve vs. standard isolation valve – difference?
A: A sanitary sampling valve has a chamber that sterilises independently before each draw. Standard valves lack this capability.

Q: How to prevent cross‑contamination between samples?
A: Sterilise the chamber before and after each sample. Flush with clean water or sterile medium after sampling.

Q: What sample volumes can it handle?
A: Small volumes typical for biopharma quality testing. Multiple draws from the same sterilised chamber are possible.

Q: Can it handle viscous products?
A: Yes – up to 1,000 cP and particles up to 3 mm. For higher viscosity, larger port size or pneumatic actuation may be preferred.

This sanitary sample valve stainless construction eliminates sampling errors through sterile chamber design, PTFE sealing, and validated SIP/CIP protocols – delivering representative samples that reflect actual batch quality.


New Type Sanitary Stainless Steel Manual Aseptic Sampling Valve

  • We manufacture Sanitary Manual Sampling Valve, Sanitary Clamp Sample Valve, Hygienic Welding Sampling Valve, Hygienic Thread Male Sampling Valve, Pneumatic Sampling Valve, Sanitary Aseptic Sample Valve.
  • The Sampling Valve allows the operator to extract a sample of the product from the production line or reactor and safely store it for transportation to the laboratory where it will be analysed or to the archive room where it can be retrieved for further use.
  • In chemical plants, a sample can be taken during the process to ensure that the output meets specifications (or that the quality is acceptable), before shipping the chemical good or before accepting the chemical product.

Product Description

Product Name: Aseptic sampling valve
Valve Body Material: SS316L
Seal Material: PTFE
Max. Working Pressure: 6Bar
Max. Working Temperature: 120 degree C
Availably connection: Weld
Operated: Manual,Pneumatic
Certificate: FDA
Feedback

Related Products

WhatsApp us

This site uses cookies

We use cookies to collect information about how you use this site. We use this information to make the website work as well as possible and improve our services.