Sanitary Hygienic Aseptic Tank Bottom Diaphragm Valve
- Model:
- JOV-SV-22
- Place of Origin:
- Wenzhou China
- Packing:
- Suitable Packing For Sea/Air Transport
- Payment:
- T/T, L/C, Western Union
- Medium:
- Water, Gas and Clean Water Sources
- Material:
- SS304, SS316, SS316L
- Connection:
- Clamp,Weld
- Temperature:
- -5~80 ℃
A sanitary diaphragm valve configured in a normally open state maintains continuous unhindered flow across fluid conduits until electrical excitation energizes an internal electromagnetic coil. Internal springs lift the sealing membrane away from raised weir faces during de-energized conditions, satisfying ASME BPE drainability mandates while providing sterile shutoff during automated Clean-in-Place (CIP) and Steam-in-Place (SIP) routines.
Sanitary Clamp Integration and Ferrule Compression
Frequent pipeline maintenance requires modular connection points that prevent product pooling. Clamped hygienic diaphragm valve configurations utilize precision-turned ferrule faces matching standard sanitary tubing dimensions.
Heavy-duty bolted clamps supply symmetrical radial pressure across elastomeric seals. Uniform compression eliminates interior gasket protrusion, maintaining flush fluid boundaries against fluctuating vacuum and pressure phases.
Continuous Coil Energization and Thermal Dissipation Performance
Holding electromagnetic actuators in closed positions requires continuous electrical input, generating internal thermal energy across the solenoid housing:
| Solenoid Coil Rating | Inrush Power Draw | Sustained Holding Power | Coil Temperature Rise |
|---|---|---|---|
| Standard 24V DC Direct | 45 Watts | 18 Watts | 42°C Above Ambient |
| Electronic PWM Pulse-Width | 45 Watts | 3.5 Watts | 12°C Above Ambient |
| Explosion-Proof Class H | 52 Watts | 22 Watts | 48°C Above Ambient |
Employing pulse-width modulation circuits reduces holding wattage, restricting steady-state coil heating. Lower operating temperatures shield fluoropolymer diaphragms from conductive heat degradation, preventing polymer creep across extended production cycles.
Loop Venting Operations and Millisecond Response Speeds
Rapid venting sequences demand immediate mechanical action without air pressure delay. Deploying direct-acting aseptic diaphragm valves delivers instantaneous seat closure within 30 milliseconds of coil energization.
Direct electromagnetic coupling eliminates pneumatic supply tubing, reducing installation space requirements inside compact cleanroom enclosures and providing repeatable fluid diversion during emergency power shutdowns.
Vessel Evacuation and Gravity Drainage Sequences
Processing vessels require fail-open bottom isolation to discharge wash fluids during unexpected facility power disruptions. Paired alongside a vessel-welded tank bottom diaphragm valve, the assembly opens instantaneously when current ceases.
The downward sweep of the internal cavity drains remaining media out through discharge lines without pooling, ensuring total fluid clearance ahead of subsequent steam sanitization sequences.
Product Description
| Operation: | Normally Open, Normally Closed |
| Power Supply Voltage: | DC12~220V; AC24V~380V |
| Body Material: | SS304, SS316, SS316L |
| Applicable Media: | Water, Gas and Clean Water Sources |
| Pressure Range: | 0~1.0MPa(NC),0~0.8MPa(NO) |
| Temperature Range: | -5~80 ℃ |
| Medium Viscosity: | Less than 50C St (customized if greater than) |
| Coil Protection Level: | Plastic sealed coil IP64/Underwater coil IP67 |
| Explosion Proof Level: | BT4/T4/BT6 |
| Wiring Method: | Wire Holder Type, Lead type,Plug type |
| Connection: | Clamp,Weld |